ENVIRONMENT
Supermicro X8DAL-i, Vista x64 (host), Windows Home Server (Windows 2003-like guest), Parallels/Virtualbox VM, 3Ware 9650 RAID-5 1TB-3, Intel IHC10R, SATA drives (1TB X2, 500GB X3), 6GB RAM, Intel 5520 (Xeon),PNY Nvidia 9600GT, PC Power 910W.
GUEST OS EVENT LOG ERRORS
event 11 - driver detected a controller error on \device\ide\IdePort1
event 9 - device \Device\Ide\IdePort1 did not respond within the timeout period (6X)
event 51 - An error was detected on device \Device\Harddisk1 during a paging operation 5X
event 50 - Delayed write failed . . . 5X
event 51 - the device Virtual HDD '0' IDE\DiskVirtual__HDD(0) FWR10003 . . . disappeared from the system w/o being first prepared for removal.
event 9 - device \Device\Ide\IdePort1 did not respond within the timeout period (6X)
event 51 - An error was detected on device \Device\Harddisk1 during a paging operation 5X
event 50 - Delayed write failed . . . 5X
event 51 - the device Virtual HDD '0' IDE\DiskVirtual__HDD(0) FWR10003 . . . disappeared from the system w/o being first prepared for removal.
HOST OS ERRORS
None
More details on the Virtualbox forum.
WORKING HYPOTHESES
- 3Ware battery backup unit failure (But timeouts happen or appear to happen on the non-3Ware drive)
- Firmware issue with SMC MBO
- VM over 3Ware RAID instability
- Special circumstance with VM and WHS
- Special circumstance with WHS
No comments:
Post a Comment